deactivation request

A deactivation request corresponds to a modification of the property. After validating of the deactivation request by the experts, the value of the calculated status of the property changes to “inactive”. The property is not deleted from the system (property archive). EXAMPLE The user found a property which is no longer applicable and proposes to […]

replacement request

A replacement request corresponds to the creation of the property and the deactivation of the property it replaces. After validation of the replacement request by the experts, the replaced property is deactivated. Its calculated status changes to “inactive”. Its PA012 attribute is automatically populated with the globally unique identifier of the property that replaces it. […]

fragmentation request

A fragmentation request corresponds to the deactivation of the property and the creation of several properties. After validation of the fragmentation request by the experts, the fragmented property is deactivated. Its calculated status changes to “inactive”. Its PA012 attribute is automatically populated with the globally unique identifiers of the properties that replace it. BS EN […]

merge request

A merge request corresponds to the creation of one property and the deactivation of several properties. After validation of the merge request by the experts, the merged properties are deactivated. The calculated status of the merged properties changes to “inactive”, PA012 attributes are then automatically populated with the globally unique identifier of the created property […]

Management of duplicates

The procedure to remove duplicate properties shall be carried out on the relevant attributes. The management of duplicates cannot be fully automated. BS EN ISO 23386:2020

International Harmonized Stage Codes

Stages: 00 PRELIMINARY 10 PROPOSAL 20 PREPARATORY 30 COMMITTEE 40 ENQUIRY 50 APPROVAL 60 PUBLICATION 90 REVIEW 95 WITHDRAWAL Substages: 00 REGISTRATION 20 START OF MAIN ACTION 60 COMPLETION OF MAIN ACTION 90 DECISION 92 REPEAT AN EARLIER PHASE 93 REPEAT CURRENT PHASE 98 ABANDON 99 PROCEED https://www.iso.org/stage-code

Product Data Template (PDT)

The document aimed to be used by manufacturers and consumers where information about a product, is collated in a standardised and structured way. The information is structured in the form of relational properties which can be connected to other data which can be automatically analysed for quality control, therefore being both machine and human-readable.

Construction Products Regulation (CPR)

Construction Products Regulation (CPR) https://ec.europa.eu/growth/sectors/construction/product-regulation_en#:~:text=The%20Construction%20Products%20Regulation%20(CPR,the%20performance%20of%20construction%20products.

exchange requirement (ER)

defined set of information units that needs to be exchanged to support a particular business requirementat a particular process phase (or phases)/stage (or stages) BS EN ISO 29481-1:2017